德國DIN EN ISO11997-1循環腐蝕測試標準及復合鹽霧測試方法

Cycle A

C.1 Salt fog test solution鹽霧試驗溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5條所述的方法制備噴霧溶液,將氯化鈉溶解在水中,使溶液的濃度為(50±10g/L,溶液的pH值在67范圍內。

C.2 Cycle

Set up the cabinet to perform the following cycle設置鹽霧箱執行以下循環
StepTime hTemp ConditionNotes
1235±2Salt spray 
2460±2Dry:20-30% 
3250±2Wet:95%RH or over 
4Go back to step 1This makes a total cycle time of 8h from step1 to step3
 Transtition time(ie time allowed to reach the temperature and relative humidity specified for a condition after changing to that condition):From salt spray to dry:within 30min
從鹽霧到干燥:30min內
From dry to wet:within 150 min
從干到濕:150分鐘內
From wet to salt spray:within 30min
從濕到鹽霧:30分鐘內
The effect of the salt spray will,in principle,be instaneous。
For details of drying-air flow,see 6.4
鹽霧的效果在原則上是瞬時的。
有關干燥空氣流量的詳細信息,請參見6.4
 

C.3 Salt fog depsiton rate鹽霧沉降率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
當鹽霧在24小時內被收集時,鹽霧的沉積速率應該是1ml/h2ml/h(見第10條)

C 4 Duration持續時間

Unless otherwise agreedrepeat the test cycle for 30 cycles(240h),60cycles(240h),90cycles(720h) or 180cycles(1440h)
除非另有約定,重復測試周期30周期(240h)、60周期(240h)、90周期(720h)或180周期(1440h

Cycle B

C.1 Salt fog test solution鹽霧試驗溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5條所述的方法制備噴霧溶液,將氯化鈉溶解在水中,使溶液的濃度為(50±10g/L,溶液的pH值在67范圍內。

C.2 Cycle

Set up the cabinet to perform the following cycle. 設置鹽霧箱執行以下循環。
StepTime hTemp Conditionnotes
12435±2Salt fog 
2840±299%RHWater condensing on test panels
31623±250±20%RH 
4840±299%RHWater condensing on test panels
51623±250±20%RH 
6840±299%RHWater condensing on test panels
71623±250±20%RH 
8840±299%RHWater condensing on test panels
91623±250±20%RH 
104823±250±20%RH 
11Go back to step 1This makes the total cycle time 7 days from step1 to step10.
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate鹽霧沉降率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)

C 4 Duration持續時間

Unless otherwise agreedrepeat the test cycle for 840 h
除非另有約定,重復測試周期為840小時。
 

Cycle C

C.1 Salt fog test solution鹽霧試驗溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (0.31±0.01)g/l and (4.1±0.01)g/l respectively  .The PH of the solution shall be in the range 6 to 7.
按照第5條所述的方法制備噴霧溶液,在水中溶解氯化鈉,濃度分別為(0.31±0.01g/L和(4.1±0.01g/L,溶液的pH值在67范圍內。

C.2 Cycle

Set up the cabinet to perform the following cycle. 設置來執行以下循環。
StepTime minTemp Conditionnotes
121030±2Salt fog 
221040±2DryDrying-air purge(see 6.4)
3147040±275±15%RHOne method of achieving this conditon is to alternate the dry and humid cycles for suitable(short)time periods to keep the RH between the limits specified
410230±2DryDrying-air purge(see 6.4)
521030±2Salt fog 
637830±290% to 99%RHWater condensing on test panel
718035±2DryDrying-air purge(see 6.4)
812025±2Dry 
9Go back to step 1This makes the total cycle time 48h from step1 to step8.
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate鹽霧沉降率

The salt fog deposition rate shall be 2ml/h to 4ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
當鹽霧在24小時內被收集時,鹽霧的沉積速率應為2ml/h4ml/h(見第10)

C 4 Duration持續時間

Unless otherwise agreedrepeat the test cycle for1000h
除非另有約定,重復測試周期為1000小時。

Cycle D

C.1 Salt fog test solution鹽霧試驗溶液

Prepare the spray solution as described in Clause 5 by dissolving sodium chloride in water to give a concentration of (50±10)g/l .The PH of the solution shall be in the range 6 to 7.
按照第5條所述的方法制備噴霧溶液,將氯化鈉溶解在水中,使溶液的濃度為(50±10g/L,溶液的pH值在67范圍內。

C.2 Cycle

Set up the cabinet to perform the following cycle,設置執行如下下循環
StepTime hTemp ConditionNotes
10.530±2Salt spray 
21.530±2Wet:(95±3%RH 
3250±2Hot dry 
4230±2Warm dry 
5Go back to step 1This makes a total cycle time of 6h from step1 to step4
 Transtition timeie time allowed to reach the temperature and relative humidity specified for a condition after changing to that condition):From salt spray to wetwithin 10min
從鹽霧到潮濕:10min以內
From wet to hot drywithin 15 min
從濕到熱干燥:15分鐘內
From hot dry to salt warm drywithin 30min
從熱干燥到鹽溫干燥:30min
From salt warm dry to salt sprayinstaneous
從鹽溫干到鹽霧:瞬時
NOTE  Set points and operational fluctuations can be listed either independently of each other or in the formatset point±operational fluctuations.The set point is the target condition for the sensor when used at the operational control point as programmed by the user.Operational fluctuations are deviations from the indicated set point at the control point indicated by the readout of the calibrated control sensor during equilibrium operation and do not include measurement uncertainty.At the operational control point , the user programmes that exat number . The operational fluctuations specified for that set point do not imply that the user is allowed to programme a set point higher or lower than the exact set point specified.
 

C 3 Salt fog depsiton rate鹽霧排放率

The salt fog deposition rate shall be 1ml/h to 2ml/h,when the salt fog iscollected over a 24h period (see Clause 10)
當鹽霧在24小時內被收集時,鹽霧的沉積速率應該是1ml/h2ml/h(見第10條)

C 4 Duration持續時間

Unless otherwise agreedrepeat the test cycle for 28 cycles(168h)
除非另有約定,重復測試周期為28個周期(168h)。

 


符合德國DIN EN ISO11997-1測試標準的循環腐蝕復合鹽霧箱
參考文章:
1、CETP 0000-L-467試驗室加速循環腐蝕試驗標準中文翻譯版
2、淺析福特汽車CETP 0000-L-467測試標準的試驗步驟及方法
3、簡析通用汽車GMW 1487標準的試驗流程及步驟

 

免責聲明

  • 凡本網注明“來源:儀表網”的所有作品,均為浙江興旺寶明通網絡有限公司-儀表網合法擁有版權或有權使用的作品,未經本網授權不得轉載、摘編或利用其它方式使用上述作品。已經本網授權使用作品的,應在授權范圍內使用,并注明“來源:儀表網”。違反上述聲明者,本網將追究其相關法律責任。
  • 本網轉載并注明自其它來源(非儀表網)的作品,目的在于傳遞更多信息,并不代表本網贊同其觀點或和對其真實性負責,不承擔此類作品侵權行為的直接責任及連帶責任。其他媒體、網站或個人從本網轉載時,必須保留本網注明的作品第一來源,并自負版權等法律責任。
  • 如涉及作品內容、版權等問題,請在作品發表之日起一周內與本網聯系,否則視為放棄相關權利。
聯系我們

客服熱線: 15267989561

加盟熱線: 15267989561

媒體合作: 0571-87759945

投訴熱線: 0571-87759942

關注我們
  • 下載儀表站APP

  • Ybzhan手機版

  • Ybzhan公眾號

  • Ybzhan小程序

企業未開通此功能
詳詢客服 : 0571-87759942